RA1630 online hydrogen oxygen analyzer
RA1630 online hydrogen oxygen analyzer
The RA1630 online hydrogen oxygen analyzer represents the latest technology in oxygen measurement, using imported high sensitivity electrochemical sensors. The intrinsically safe probe has high accuracy, resistance to weak acid and alkali corrosion, and can be used for oxygen content measurement in many fields. It is widely used in hydrogen production stations in power plants and industrial oxygen content measurement.Technical Specifications | Values |
---|---|
Measurement Range | 0% to 2% VOL O2 |
Precision | ± 0.03% |
Repeatability | ± 0.01% |
Response Time | 20 seconds |
Analog Output | 4 mA to 20 mA (Max load 800Ω) |
Alarm Output | DC 24V 1A (Two alarm outputs, independently programmable) |
Operating Temperature | -10°C to 40°C |
Protection Level | NEMA 4X, IP 66 |
Explosion-proof Level | Ex ia ⅡC T 6 Ga |
Installation Method | Control Unit: Panel mounted on control cabinet, Cutout size: 92mm×92mm |
Sampling System: Wall mounted on site, Dimensions: 600mm×450mm×120mm |
Other features:
- Explosion proof and intrinsically safe sensing units
- High measurement accuracy, anti-interference, and fast response speed