TCS101 thermal conductivity hydrogen purity sensor
Thermal conductivity hydrogen purity sensor
TCS101 thermal conductivity hydrogen purity sensor is a gas purity sensor designed using MEMS technology. It does not require a reference gas and has advantages such as a wide measurement range and flexible configuration. It adopts a constant temperature chamber design, which can ensure measurement accuracy at ambient temperatures (-20~50) C. Widely suitable for gas analysis, online monitoring, industrial process analysis and other applications.
Parameter Name | Parameter Value |
---|---|
Detected Gas | Hydrogen (H₂) |
Measurement Range | (0~100)% Vol |
Preheating Time | < 2 minutes |
Stable Time in Thermostatic Chamber | < 10 minutes (12VDC, room temperature) |
Recommended Flow Rate | (50-500) mL/min |
Linearity Error | < ±0.1% F.S. |
Response Time (T90) | < 21 seconds (@500 mL/min) |
Repeatability | < 0.2% (relative standard deviation) |
Minimum Detection Limit | 0.2% F.S. |
Resolution | 0.01% |
Operating Voltage | (7~12) VDC |
Operating Current | Max 2.4A (average 200mA) @12V |
Average Power | < 2.5W |
Peak Power | < 40W |
Signal Output Method | MODBUS RTU @ RS-485 |
Operating Temperature | (-20~50)°C |
Operating Humidity | (0~95)% RH (non-condensing) |
Storage Temperature | (-40~80)°C |
Dimensions | 106mm*85mm*71mm (L*W*H) |
Weight | 470g |
Other features:
- Adopting a constant temperature chamber design, it can ensure reliable measurement results at -20 ℃~+50 ℃;
- Sensor has no obvious usage consumption and a service life of more than 10 years;
- Designed using MEMS technology, without the need for reference gas, with a wide measurement range and flexible configuration.